Postgres Cross Data Center Disaster Recovery (DC-DR)

KubeDB can run one PostgreSQL database across two data centers (DCs) and move it between them, either on request (planned switchover) or automatically when the active data center is lost (unplanned failover). This feature is called DC-DR.

This page explains how DC-DR is built, what each component does, how split-brain is prevented, what to expect for data loss (RPO) and recovery time (RTO), and the current limitations. The other pages in this section walk through a complete installation:

  1. Concepts (this page)
  2. Build the stretched hub
  3. Set up the spoke clusters
  4. Install KubeDB and dr-controlplane
  5. Provision a DC-DR Postgres
  6. Switchover and failover
  7. Horizontal scaling
  8. Update version
  9. Backup, archiving and PITR
  10. Teardown

A distributed Postgres can also run without DC-DR, as one Raft group spread across clusters with no data center failover. See Distributed Postgres without DC-DR.

Topology

          DC A                         DC B                       DC W
   +----------------+           +----------------+          +------------+
   | hub-a          |           | hub-b          |          | etcd-w     |
   |  k8s control   |           |  k8s control   |          |  etcd only |
   |  plane + etcd  |<--------->|  plane + etcd  |<-------->|  (tie-     |
   |  hub workloads |   etcd    |  hub workloads |   etcd   |  breaker)  |
   +----------------+           +----------------+          +------------+
           |  one Kubernetes cluster ("hub") over hub-a + hub-b
           |  OCM hub, KubeDB, dr-controlplane, KubeSlice controller
           |
   +----------------+           +----------------+
   | spoke-1        |  slice    | spoke-2        |
   |  Postgres x2   |<--------->|  Postgres x2   |
   +----------------+ WireGuard +----------------+
  • Stretched hub. One Kubernetes cluster, the hub, whose control-plane nodes sit in DC A and DC B. Its etcd has one member in each of three sites (DC A, DC B and a third site, DC W, that runs etcd only). Losing any one site keeps etcd quorum, so the hub keeps working. The hub runs the management components (OCM hub, KubeDB, dr-controlplane, KubeSlice controller) and holds the failover authority (see The failover authority). It runs no database pods.
  • Spokes. One Kubernetes cluster per data center (spoke-1 in DC A, spoke-2 in DC B). The database pods run here. Each spoke is registered with the hub as an Open Cluster Management (OCM) ManagedCluster.
  • Arbiter data center. A DC-DR Postgres needs two data-bearing data centers plus a third, data-less one that only breaks ties. In this guide the hub itself is registered as a ManagedCluster named hub and used as the Arbiter data center. It holds no data and can never become primary. The real third-site vote is the etcd member in DC W.
  • Pod delivery. The PetSet controller on the hub places every database pod (and its Secrets, ConfigMaps and RBAC) on a spoke through OCM ManifestWorks, following a PlacementPolicy.
  • Networking. KubeSlice connects the pod networks of the hub and the spokes with a WireGuard slice. Services exported on the slice are resolvable from every cluster as <name>.<namespace>.svc.slice.local. Replication between data centers, and the hub operator’s connections to the databases, use this network. Applications connect to <db>.<namespace>.svc.slice.local, which always points to the current primary.

A data center is identified everywhere by one name: its OCM ManagedCluster name (for example spoke-1). The same string is the clusterName in the PlacementPolicy, the holder of the failover Lease, the --dc-name of that data center’s agent, and the value of the pod label open-cluster-management.io/cluster-name. Choose the names before you start, and keep them identical everywhere.

How a DC-DR Postgres is laid out

A distributed Postgres (spec.distributed: true) becomes a DC-DR database when its PlacementPolicy has a failoverPolicy; KubeDB then sets the annotation dr.kubedb.com/enabled: "true" on it. (Setting the annotation yourself also turns DC-DR on.) A distributed Postgres whose PlacementPolicy has no failoverPolicy is a plain distributed database; see Distributed Postgres without DC-DR. KubeDB expands a DC-DR database on the hub into:

  • one PetSet per data-bearing data center, named <db>-<dc> (for example pg-docs-spoke-1), with its own PlacementPolicy <policy>-<dc>, derived from the PlacementPolicy <policy> that you create;
  • an arbiter PetSet <db>-<dc>-arbiter in a data center whose replica count is even, so that the data center’s own Raft group always has an odd number of voters.

Each data center runs its own Raft group in the pg-coordinator sidecar of its pods. Raft never stretches across data centers:

  • In the active data center, the Raft leader is the only writable primary. It carries the pod label kubedb.com/role: primary.
  • In the standby data center, the Raft leader is a read-only standby leader. It streams WAL across data centers from the active primary through a replication slot named after its data center (for spoke-1, dcdr_spoke1), and the other pods of that data center cascade from it.
  • If the primary pod fails, its own data center’s Raft elects a new local primary within seconds. The active data center does not change.

The failover authority: the primary-DC Lease

Which data center is active is decided by one Kubernetes Lease on the hub, in the namespace dc-failover:

  • primary-dc for databases that do not name a failover group, or
  • primary-dc-<group> for databases whose PlacementPolicy sets failoverPolicy.failoverGroupRef.name: <group>.

The Lease’s holderIdentity is the active data center. The Lease is stored in the hub’s three-site etcd, so a partitioned minority of sites cannot change it. All databases that share a Lease (a failover scope) always fail over together. Give every database its own failoverGroupRef unless you want them to move together; KubeDB reports a shared scope through the condition DCDRFailoverScopeShared on the Postgres object.

The Lease is maintained by the dr-controlplane agents, one per data center (the Arbiter data center included):

  • Each agent renews a health Lease dc-health-<dc> (15 s duration, renewed every 5 s).
  • Each agent of a Member data center contends for the scope’s primary-dc* Lease with a 45 s lease duration, a 40 s renew deadline and a 5 s retry period. Arbiter and Witness data centers never contend.
  • Each agent copies the current holder into a local marker ConfigMap, dc-failover/primary-dc (or primary-dc-<group>), on its own cluster. The marker carries activeDC, renewTime and, during a planned switchover, quiesce.

The database pods never look across data centers to decide whether they may write. pg-coordinator reads only the local marker, and it fails closed: if the marker is missing, unreadable, names another data center, or is older than 30 s, the data center is treated as not active.

Components

ComponentRuns onRole
etcd (three sites)hub-a, hub-b, etcd-wStores the hub’s API data, including the failover Leases.
OCM (cluster-manager, klusterlet, work agent, addon framework)hub and every clusterRegisters clusters, delivers database pods and objects with ManifestWorks, installs add-ons.
KubeSlice (controller on the hub; worker, gateway and slice DNS in each cluster)hub and every clusterCross-cluster pod network and *.slice.local DNS.
PetSet controllerhub (part of the KubeDB chart)Places pods on spokes per the PlacementPolicy; ships the PetSet, PlacementPolicy and FailoverGroup APIs.
KubeDB provisionerhubCreates the per-DC PetSets, arbiters and RBAC, and runs the DC-DR orchestrator: status, planned switchover, promotion after a failover.
KubeDB ops-manager and webhook serverhubPostgresOpsRequests and validation.
pg-coordinatorsidecar in every Postgres podIntra-DC Raft and failover, fencing, write-lock, rejoin (pg_rewind).
dr-controlplane topology controllerhubCreates one primary-DC Lease per failover scope from the PlacementPolicies; runs the FailoverGroup controller.
dr-controlplane addon managerhubInstalls the agent on every labelled ManagedCluster as an OCM add-on, with a hub credential.
dr-controlplane agentevery cluster, the hub includedRenews dc-health-<dc>, contends for primary-dc*, writes the local marker ConfigMaps.

Planned switchover

A planned switchover moves the active data center without losing acknowledged writes: none was lost in testing. The handoff allows up to 8 KiB of WAL that the target has not replayed yet (in practice checkpoint and autovacuum records); set dr.kubedb.com/switchover-zero-rpo-lag-bytes: "0" on the Postgres to require an exact catch-up. You request it with the annotation dr.kubedb.com/switchover-to=<dc> on the Postgres object. The orchestrator then:

  1. asks the active data center to quiesce; pg-coordinator write-locks the active primary (default_transaction_read_only) and ends write transactions;
  2. waits until the target data center has replayed to within 8 KiB of the frozen primary position;
  3. hands the primary-DC Lease to the target data center;
  4. promotes the target data center’s leader and rewinds the old primary into a standby. The old primary stays up, write-locked, for about 2 minutes after the handoff before it restarts as a standby.

A switchover that cannot finish is aborted automatically after 10 minutes, and you can abort it at any time with dr.kubedb.com/switchover-abort. Writes then resume on the original data center.

Unplanned failover

When the active data center is lost:

  1. Its agent stops renewing the primary-DC Lease.
  2. After the 45 s lease duration, the other Member data center’s agent acquires the Lease.
  3. The markers flip, and the orchestrator on the hub promotes the surviving data center’s cross-DC streamer. It may do this through a ForceFailOver PostgresOpsRequest named <db>-dcdr-failover-<suffix>.
  4. When the lost data center comes back, its pods rejoin as standbys of the new active data center. An old primary whose history diverged is brought back with pg_rewind.

Split-brain protection

DC-DR guarantees that two data centers are never writable at the same time. Several mechanisms work together.

Fence before promote. If the active data center is cut off from the hub but keeps running, its marker stops being refreshed:

  • 30 s after the last Lease renewal it observed, the marker is stale and the data center is no longer considered active;
  • 10 s later, pg-coordinator write-locks the primary and terminates open write transactions;
  • the Lease cannot be acquired by the other data center until its 45 s duration has passed, plus up to one 5 s retry.

So the isolated primary stops accepting writes before the other data center can be promoted. If the uncertainty lasts longer (60 s for a stale marker, 90 s for a missing one), pg-coordinator also removes the primary label from the pod.

Raft inside each data center. Within each data center, pg-coordinator runs Raft with the Pre-Vote phase enabled. A member that wants to start an election first runs a pre-vote round without increasing its term, and a real election follows only if a majority of its peers would vote for it. A pod that was cut off and has fallen behind cannot win that round, so when it reconnects it does not disrupt the healthy cluster with a needless election. Raft’s CheckQuorum option is not enabled. Protection against a stale leader across data centers comes from a lease instead: only the data center that holds the time-bound primary-dc Lease may be writable, and a primary that can no longer confirm that Lease write-locks itself before the Lease can expire and be acquired by another data center.

Only Members can be primary. Only data centers with role: Member in the PlacementPolicy contend for the Lease. An Arbiter never holds data and never becomes primary.

Nothing at the database level moves the Lease. A crashed Postgres, replication lag or failed health checks do not move the Lease; only a data center that stops renewing (or a planned switchover or handoff) does. A failed primary inside a healthy data center is replaced by that data center’s own Raft.

A third site breaks ties. The Lease lives in the three-site etcd. During a network partition, only the side that still has an etcd majority can renew or acquire it. The etcd members use Pre-Vote (--pre-vote=true): before disrupting the cluster with a real election, a member asks the others whether they can still see the leader, and only an unopposed candidate starts the election. Raft prevents a stale or isolated leader with CheckQuorum, which the etcd server always enables: a leader that loses the majority steps down, and members ignore vote requests while their leader lease is still valid. See etcd and Raft settings.

Data loss (RPO) and recovery time (RTO)

Cross data center replication is asynchronous. The numbers below were measured with KubeDB v2026.10.12 on a test installation of this guide’s topology (three single-site VMs with sub-millisecond latency between them), with a writer that records every acknowledged write. They are the numbers of that release; expect similar figures, not identical ones, on later releases and on your network.

ScenarioData lossRecovery
Planned switchoverNone (0 acknowledged writes lost in every run)Steady on the new data center in 11-15 s; writes paused for about 15 s
Primary pod failure inside the active data centerNoneNew local primary writable in 4-6 s; the active data center does not change
Loss of the active data center (VM reboot)Writes not yet streamed to the other data center (0 lost in the test)Other data center writable after about 80 s; protected again after about 3.5 minutes
Active data center isolated by a network cut, still runningWrites acknowledged inside the isolated data center between the cut and the write-lock, about 40 s (184 rows in the test). Writes made through the other data center are not affectedWrite-lock about 40 s after the cut; the other data center writable about 67 s after the lock

Clients connect through <db>.<namespace>.svc.slice.local. After every primary move, this name takes about 30 s to resolve to the new primary, even when the database itself is writable sooner. Configure your applications to retry connections.

You can bound the loss of an unplanned failover with spec.replication.bestEffortCrossDCLagBytesForFailover; see Switchover and failover.

Status

The Postgres object reports the DC-DR state in status.disasterRecovery:

FieldMeaning
activeDCThe data center that holds the primary-DC Lease.
phaseSteady, FailingOver, FailingBack or Degraded. Steady requires confirmed protection.
protectedtrue when another Member data center is confirmed streaming within the lag budget. Treat a missing value as false before any planned operation. For about a minute after a switchover or failover it can read true before the old data center has rejoined; see Check before you start.
protectionMessageWhy protected has its current value.
dataCenters[]One entry per data center: clusterName, role, leader, writable, crossDCStreamer, lagBytes, healthy (the freshness of its dc-health-<dc> Lease), notReadyPods.

Limitations

  • Two data-bearing data centers. This guide covers failoverPolicy.mode: TwoDC: exactly two Member data centers and one Arbiter.

  • Day-2 operations. These PostgresOpsRequest types work on a DC-DR database:

    • Restart;
    • Reconfigure (applyConfig, configSecret, removeCustomConfig);
    • RotateAuth, with a generated or a user-provided auth Secret;
    • ReconfigureTLS;
    • VerticalScaling, in mode Restart only: mode: InPlace is refused, and so is verticalScaling.arbiter on a database that has no per data center arbiter;
    • VolumeExpansion, in mode Online only: Offline is refused, and so is volumeExpansion.arbiter on a database that has no per data center arbiter;
    • UpdateVersion, minor and major; a major update needs manual steps, see Update version;
    • HorizontalScaling, per data center only, see Horizontal scaling.

    A refused request fails at once with the condition DCDRRequestRefused, before anything is paused. Read replicas are not supported on a DC-DR database. Run one request at a time, and only when the database is Ready, Steady and protected. A request that restarts pods steps aside (fails) when a failover, failback or planned switchover to another data center starts; apply it again once the database is Steady.

  • Hub components are single-replica. Restarting any of them does not move the primary or lose writes, but the loss of a hub VM that runs them was not tested.

  • OCM uses one hub API address. The klusterlets register against a single hub API server URL. Use a VIP, a load balancer or a DNS name for production so that the loss of one hub node does not cut the klusterlets off.

  • Switchover target. A switchover to a data center that is not a streaming Member (for example the Arbiter) never starts: the database stays Steady, the orchestrator logs that the target has no lag report and retries, and the switchover-to annotation stays until you remove it.

  • Leftover group Leases. When you delete the last database of a failover group, its primary-dc-<group> Lease and marker ConfigMaps stay behind. See Teardown.

  • Backup. Full backups, WAL archiving and PITR work with KubeStash, with limitations; see Backup, archiving and PITR.

  • Monitoring. spec.monitor works as on a single-cluster Postgres. KubeDB builds the stats Service on the hub from the per-pod Services exported on the slice (<db>-<dc>-<ordinal>).

Next Steps